KONST
AI Training CalculatorContact Us
EN
← Back to BlogBLOG | GPU Compute · 2026-11-24

Why GPUs Are Underused: Utilization, MFU, and Cluster Network Bottlenecks

Understand GPU utilization versus MFU, isolate data and network bottlenecks, and measure useful output before expanding a GPU cluster.

GPU utilization, model FLOPs utilization, and cluster network bottlenecks

Common reasons for underused GPUs include slow data delivery, waiting for communication between nodes, checkpoint writes, and idle resources caused by scheduling and queues. Measure where time is spent before deciding whether to improve data pipelines, networking, or scheduling, or add GPUs.

The business goal is to complete more useful work at an acceptable cost and quality. Read GPU utilization alongside training throughput, completion time, inference latency, and failed work that must be rerun.

GPU utilization and MFU answer different questions

GPU utilization describes how busy the device is during a sampling period. Model FLOPs Utilization (MFU) measures useful model computation during training relative to theoretical peak performance. A high activity reading is a useful clue, but it still needs to be checked against output.

Under NVIDIA SMI’s definition, GPU utilization is the percentage of the sampling period during which at least one kernel was executing. A high reading alone does not show whether all compute resources are being used effectively or whether execution is producing the expected output.

The PaLM paper introduced MFU to count the model’s required forward and backward computation while excluding extra recomputation used to save memory. This avoids treating additional recomputation as additional useful training.

Calculate MFU with clear comparison conditions

MFU can track system efficiency under the same training setup, but the percentage needs a definition of the model, numerical precision, throughput, and theoretical peak. Without those conditions, results from two reports are difficult to compare.

MFU = tokens processed per second × model FLOPs required per token ÷ combined theoretical peak FLOPs/sec of all accelerators.

For example, suppose useful model computation reaches 400 trillion operations per second and the equipment’s combined theoretical peak at the same precision is 1,000 trillion operations per second. MFU is 40%. This is an illustrative calculation, not a recommended threshold or a measured product result.

PaLM 540B reported 46.2% MFU on 6,144 TPU v4 chips in its research configuration. That is a result for a particular model and system, not an acceptance threshold for every GPU cluster. See Section 4.1 and Table 3 of the paper for the original definition and results, consulted on November 5, 2026.

Before comparing results, confirm precision, sparse-computation assumptions, model architecture, sequence length, batch size, and measurement period. Report steady-state training MFU separately from end-to-end efficiency that includes initialization, checkpointing, failures, and reruns.

Isolate communication bottlenecks from one node to many

When the same model performs as expected on one node but slows after moving across nodes, communication deserves investigation. Establish an intra-node baseline, then test multiple nodes within one rack and across racks to narrow the problem.

For illustration, suppose a training job grows from 8 to 16 GPUs, but throughput rises from 1,000 to 1,300 tokens per second: only 1.3 times the original throughput. These are hypothetical values, not a benchmark or performance commitment. They justify investigating the time breakdown; they do not, by themselves, prove a network problem.

Compare data-loading, compute, and communication time per step. Then run NCCL tests under consistent conditions on a single node, multiple nodes in one rack, and across racks. If data loading accounts for most of the wait, address the pipeline first. If communication takes a much larger share across nodes, inspect the interconnect topology, links, and parallelism strategy.

Scale-up focuses on GPU communication within a high-speed interconnect domain, such as NVLink/NVSwitch. Scale-out connects a wider set of nodes over networks such as InfiniBand or Ethernet. A rack-scale system’s scale-up domain can span several compute trays, so the boundary is not simply “inside or outside one chassis.”

NVIDIA’s NCCL tutorial tests single-node, single-rack, and multi-rack configurations. Keep GPU count, node configuration, message size, and software versions consistent when comparing collective communication, so differences in test conditions are not mistaken for network degradation.

NCCL bus bandwidth, reported as busbw, applies a conversion for the collective operation to help interpret communication efficiency. It differs from algorithm bandwidth, which divides application data volume by elapsed time. Procurement and troubleshooting comparisons need the same operation and scale; a single network adapter’s advertised bandwidth is not an all-reduce acceptance threshold.

Data, checkpoints, and scheduling also reduce useful output

Data preparation, storage writes, and waiting for nodes can all prevent expensive GPUs from working continuously. Include waits and reruns in the analysis to identify which improvement will reduce project time most.

When data loading cannot keep up, each training step may wait for reads, decompression, or preprocessing. Test storage with data formats and access patterns close to production. For checkpoints, examine both write time and recovery capability: saving less often can increase the work lost after a failure.

A slower node can also hold back a synchronized multi-node job. Align step times, communication waits, and error logs across nodes. At the scheduling layer, examine queues, fragmented capacity, and faulty-node isolation. These issues require different remedies.

Measure and fix before expanding

Select a representative workload and rule out bottlenecks layer by layer before buying more GPUs. Keep comparison conditions consistent after each change and confirm that output improves.

SymptomCheck firstDecision before expansion
Intermittent GPU waitsData loading and preprocessingCan the pipeline sustain target throughput?
Good single-node performance, slower across nodesComparable NCCL tests and communication waitsImprove interconnect or parallelism, then assess added GPUs
Throughput drops during savesCheckpoint write and recovery timeBalance save cost against acceptable rework
Frequent queues or rerunsScheduling, node errors, recovery recordsUse end-to-end completion time to confirm a capacity gap

Training and inference need different measures

MFU adds context to training efficiency. Online inference must also meet latency, concurrency, and quality requirements. Keeping headroom for demand spikes may lower average utilization while helping maintain response times.

For inference, track time to first token, subsequent token generation speed, and throughput at the required latency target. For training, track completion time, step time, useful token throughput, and recovery cost. MFU comparisons across models need explicit architecture and FLOPs-estimation assumptions; one percentage cannot determine which model or platform is best.

When a model moves to multiple nodes, measure the value of added capacity

When a business spreads a large model across GPUs or expands training across servers, fitting the model is only the first requirement. It also needs to measure how much throughput the added resources deliver and how much communication waiting they introduce. This is where GPU activity, MFU, and end-to-end output serve different purposes.

Glows.ai, KONST Group’s GPU cloud platform partner, provides a guide to measuring latency and throughput. It explains how to record time to first token, p95 latency, and output tokens per second while keeping the model version, inference engine, test inputs, and number of concurrent requests fixed. Teams can use the same conditions before and after adding GPUs to check whether extra resources improve output. When scaling to multiple servers, repeat those measurements and account for time spent waiting for cross-node communication to understand why throughput may grow more slowly than the GPU count.

For dedicated cluster deployment, the GPU cluster build service from KONST’s infrastructure brand, Konstra AI, includes topology design, cabling, and NCCL cross-node bandwidth reports. These provide evidence of communication performance between servers.

Contact KONST to discuss GPU cluster and interconnect configurations for multi-node model deployment.

GPU ComputeGPUPerformanceNetworking

Plan the Next Stage of Compute Together

Where Efficiency Leads.
Where AI Defines the Future.