Annual term, priced per GPU-hour
Rental terms are measured in years. Pricing is per GPU-hour and settled monthly.
Bare Metal GPU Rental
A single client receives exclusive use of the full group of GPU servers. The physical machines, not virtualized slices, run in a KONST data center with their full performance available. The client connects through a dedicated VPN and manages everything above the operating system. KONST retains ownership of the equipment.
KONST handles server installation, the initial operating system, drivers, the base environment, an isolated network segment, and a dedicated VPN. After connecting, the client chooses the frameworks, scheduler, and data storage.
Rack the servers, install drivers and the base environment, and configure an isolated network segment and dedicated VPN.
Connect through a remote account and choose framework versions, scheduling tools, and data storage.
Use NCCL to measure cross-node bandwidth and latency, then move into production after acceptance.
Terms are annual, priced per GPU-hour and settled monthly. Most contracts include take-or-pay: the client pays for contracted capacity, the equipment is not offered to anyone else during the term, and the client controls scheduling.
Rental terms are measured in years. Pricing is per GPU-hour and settled monthly.
Under take-or-pay, charges follow contracted capacity rather than actual hours used that month. The equipment remains exclusive throughout the term.
Longer terms have lower unit prices, and fees are prepaid at the start. The term and project schedule are aligned before signing, and the contract states how payments are handled after early termination.
Rented equipment sits on an isolated network segment, separated from other tenants at the network layer. All external access uses a dedicated VPN, so data does not cross the public internet. Cluster nodes communicate over a high-speed network, and a separate circuit can connect an existing data center.
Rented equipment occupies a dedicated network segment, separated from other tenants' traffic at the network layer.
All external connections use a dedicated VPN, keeping data off the public internet. Cluster nodes communicate over a high-speed network.
A dedicated circuit can carry large data transfers to the owner's existing data center without using the public internet.
Available accelerators include H100, H200, B200, and B300. The table shows a complete H200 node configuration. Other models differ in accelerator generation, power, and cooling and are configured for the project scale and site.
| Item | Specification |
|---|---|
| Accelerator | HGX H200 |
| Processor | Dual Intel Xeon 8558P, 48 cores |
| Memory | DDR5-5600 ECC |
| System drive | M.2 SSD |
| Network interface | 400G dual-port, ConnectX-7 with BlueField |
| Power supply | 3200W Titanium |
| Security module | TPM 2.0 |
Note: This is a reference H200 node configuration. The project quotation defines the actual delivery specification.
Completed projects include a one-year H100 contract at roughly 100-server scale in Taiwan, long-term contracts running alongside the platform in KONST's Taichung data center, and a B300 site at roughly 100-server scale in Malaysia. KONST retains equipment ownership, while clients use the capacity to serve their downstream customers.
The one-year delivery includes initial operating system installation, an isolated network segment, and a dedicated VPN. KONST retains the equipment, and the client serves downstream customers.
The self-built Taichung facility supports long-term contracts and the cloud platform at the same time. Contracts cover base capacity, while remaining capacity is offered through the cloud platform.
After installation, the full block of capacity is offered under a single rental agreement.
Bare metal provides physical machines with no virtualization layer, so all performance is available, but the client manages the operating system and cluster. GPU cloud is preconfigured and quick to provision, but resources are shared with other tenants. Long-running training at full load generally uses bare metal.
Consider data residency, network latency, and support hours. If data cannot leave the country, equipment location is mandatory. Local connections have lower latency than transoceanic links, and the support team works in the same time zone as the client.
Additional GPUs are usually added as new nodes and priced under the existing contract, subject to available capacity. Take-or-pay limits reductions, so clients usually adjust downward at renewal.
KONST retains ownership. The client pays for usage rights, including data center space, power, network, and operations. KONST bears procurement funding, residual-value, and generational-refresh risk.
KONST installs the operating system, drivers, and base environment, then configures an isolated network segment and dedicated VPN. The client manages frameworks, scheduling, and data storage after handover.
Tell us the model, quantity, and term. We will respond with an available configuration and provisioning schedule.